Rack UPS

Short Description:


Technical Parameters

MODEL C3KS Rack C6KS Rack C10KS Rack
Manufacturing Year 2018 2018 2018
Type Online/Rack Online/Rack Online/Rack
BRAND SANTAK SANTAK SANTAK
PHASE Single phase with ground Single phase with ground Single phase with ground
CAPACITY* 3000VA/2400W 6000VA/5400W 10000VA/9000W
INPUT
Nominal voltage 220VAC 220VAC 220VAC
Input voltage Range 110-300VAC±3% at 50% load
176-300VAC±3% at 100% load
110-300VAC±3% at 50% load
176-300VAC±3% at 100% load
110-300VAC±3% at 50% load
176-300VAC±3% at 100% load
Frequency Range 46-54Hz or 56-64Hz 46-54Hz or 56-64Hz 46-54Hz or 56-64Hz
Power Factor ≧ 0.98 @ nominal voltage (100% load) ≧ 0.99 @ nominal voltage (100% load) ≧ 0.99 @ nominal voltage (100% load)
OUTPUT
Output voltage 208/220/230/240VAC 208/220/230/240VAC 208/220/230/240VAC
AC Voltage Regulation ±1% (Batt. Mode) ±1% (Batt. Mode) ±1% (Batt. Mode)
Frequency Range(Synchronized Range) 46-54Hz or 56-64Hz 46-54Hz or 56-64Hz 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50Hz±0.1Hz or 60Hz±0.1Hz 50Hz±0.1Hz or 60Hz±0.1Hz 50Hz±0.1Hz or 60Hz±0.1Hz
Current Crest Ratio 3:1 3:1 3:1
Harmonic Distortion ≦3%THD(linear load); ≦5%THD(non-linear load) ≦3%THD(linear load); ≦5%THD(non-linear load) ≦3%THD(linear load); ≦5%THD(non-linear load)
Transfer Time AC Mode to Batt. Mode 0ms 0ms 0ms
Inverter to Bypass 0ms 0ms 0ms
Waveform (Batt. Mode) Pure Sinewave Pure Sinewave Pure Sinewave
EFFICIENCY
AC Mode 91% 92% 93%
Battery Mode 88% 90% 91%
Display Description
LCD panel UPS status、load size、battery capacity、input and output voltage, unloading time、fault condition UPS status、load size、battery capacity、input and output voltage, unloading time、fault condition UPS status、load size、battery capacity、input and output voltage, unloading time、fault condition
Test
Test mode Automatic and manual(Test by button and LCD panel) Automatic and manual(Test by button and LCD panel) Automatic and manual(Test by button and LCD panel)
BATTERY
Long-run Model Battery Type 12V 18Ah 12V 18Ah 12V 26Ah
Battery Numbers 8*1 8*2 8*2
PHYSICAL
Long-run Model Dimension,D*W*H 438*420*87(mm) 482.6*600*130(mm) 438*86.2*573(mm)
Net Weight(kgs) 9 19.2 15
ENVIRONMENT
Operation Humidity 0-95% RH @ 0 – 40℃ (non-condensing) 0-95% RH @ 0 – 40℃ (non-condensing) 0-95% RH @ 0 – 40℃ (non-condensing)
Noise Level Less than 50dBA @ 1 Meter Less than 55dBA @ 1 Meter Less than 55dBA @ 1 Meter
MANAGEMENT
Smart RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
Optional SNMP Power management from SNMP manager and web browser Power management from SNMP manager and web browser Power management from SNMP manager and web browser
Long-run model is only available in 200/208/220/230/240VAC systems.
*Derate capacity to 80% of capacity in Frequency converter mode or when the output voltage is adjusted to
100/200/208VAC.
Product specifications are subject to change without further notice

  • Previous:
  • Next:

  • WhatsApp Online Chat !